Secure Supply Kenya
Fueling Healthy Communities
Power Gas Architecture | Developer
Secure Supplies Group
Mr Derrick James Kimani,
Nairobi , Kenya +254 721 661501
NON ELECTROLYTIC SCALE REMOVER & 100% CHEMICAL FREE SCALE SEPARATION / REMOVAL
Voltrolysis generates Oxidants in the water; Oxidants mitigate the Corrosion, Bio-fouling, Micro-Organism growth, Scaling, & spread of airborne bacteria in Circulating water structures.
Secure Supplies ® established its operation right from its inception in 2003 with well-equipped latest in-plant facilities & qualified engineers in offering Quality, Economy & Delivery of electro chemical equipment, Engineering equipment and Turnkey Projects under single platform.
Recently Secure Supplies ventured and developed a NON Electrolytic Scale Remover. It removes the scale by Non electrolytic operation with Zero Chemical. It generates Oxidants in the water; Oxidants mitigate the Corrosion, Bio-fouling, Micro-Organism growth, Scaling, & spread of airborne bacteria.
/// ABOUT Secure Supplies Non Electrolytic Descaling
With over two decades of design and manufacturing expertise, Secure Supplies became a leading global provider of water solutions including…
♦ Non Electrolytic Organic and Inorganic Colour removal,
♦ Non Electrolytic sewage treatment,
♦ Non Electrolytic Drinking water Disinfection,
♦ Non Electrolytic Treatment of zero discharge,
♦ Non Electrolytic Contaminants Removal,
♦ Non Electrolytic removal of scales.
In the field of Scale Removal or scale reduction, our Voltrolysis Units are proven their performance with many different customers
worldwide in…
♦ Cooling tower water treatment,
♦ Pre-treatment of RO (Reverse Osmosis) water feed.
♦ Hot and cold water system water treatment,
♦ Heavy metal removal,
The company directors and engineers are professionals, highly experienced in the development and marketing of electrochemical and engineering equipment.
I put this here for you to think about your Flow rate needs and email to me here so we can offer the most suitable solution .
I put this here for you to think about your Flow rate needs and email to me here so we can offer the most suitable solution .
Potential Benefits of NON Electrolytic Scale Remover
-
100% savings on chemicals.
-
No need of softeners.
-
60 to 70% savings on blow-down water.
-
10 to 50% savings on labor cost.
-
20 to 40% of water savings.
-
05 to 15% of energy savings of cooling fan.
-
02 to 30% energy savings on cooling energy.
-
02 to 20% saving on boiler energy in power plants.
PROCESS CHEMISTRY:
By applying a Specific VIC Stanley A Meyer Voltrolysis Technology.
Electrical polarized power between the anode and the cathode, a chemical reaction is activated and Voltrolysis process takes place. We there is no dead short and high voltage and low amps. Creating effcient H2 and o2 Release from water. Thus allowing PH manipulation to take place with out added electrolyte.
Water from the cooling tower pond is circulated through the Voltrolysis scale remover Reactor . Due to the Voltrolysis process, the floating calcium molecules get deposited on the cathode and other minerals fall out of solution and the water returns to the cooling tower, reduction of calcium.
The chemical reaction on Voltrolysis cathode is as follows:
Ca(HCO3)2+2OH ↓→ CaCO3 + 2H2O + CO3 2
Mg(HCO3)2+2OH ↓→ Mg(OH)2 + 2H2O + CO3 2
* Positive Charged Water making contaminates fall out of solution.
This System is also ideal for Extracting Lithium Gold and other mentals like Magnesium from water as well as calcium scale.
Any Chlorine in water forms hypochlorous acid (HOCl) and hydrochloric acid (HCL).
When this solution of HOCl and HCL reacts for a sufficient time with and excess of limestone (calcium carbonate)
the reaction is: 2Cl2 + 2H2O + 2CaCO3 _ 2HOCl + CaCl2 + Ca(HCO3)2
Typical mineral scales in hot and cold domestic water distribution systems and also in evaporative cooling systems are largely calcium carbonate.
Therefore, injecting a solution, even a dilute one, of HOCl and HCl should produce the same reaction.
In the presence of an excess of calcium carbonate
(nearly always the case in scaled water distribution and recirculation systems)
and an excess of calcium bicarbonate indigenous to the water supply, the HCl would react as follows:
2HCl + Ca(HCO3)2 = CaCl2 + 2H2O + 2CO2 Calcium chloride and carbon dioxide solubility are rather high, so these reactions of HOCl and HCl would tend to decompose calcium carbonate scale to form rather soluble calcium chloride.
The reaction of HCl with bicarbonate alkalinity should result in a reduction of alkalinity of about a 1 ppm HOCl to 1 ppm HCO3- ratio.
This would have a rather insignificant effect on pH, but any pH reduction could aid the calcium carbonate resolution rate.
HOW Secure Supplies System WORKS:
* Accelerated scale precipitation within the reactor.
* Production of active alkaline ionic species
- enabling automatic active pH manipulation to control corrosion.
* Continuous online generation of active oxidants - as a replacement to biocides and oxidizing agents.
TECHNICAL INNOVATION:
* Proprietary Ultra-Short Pulsed and Gated High Voltage DC Technology
with Bifilar Balum Chokes.
* Highly Efficient Oxidation - Reduction Process.
* Cold Electrochemical Activation System.
* Positive Charged Water making contaminates fall out of solution.
* Functionalized Electrodes Design.
* Self-Cleaning Electrodes.
* Self Additional By Product of Pure H2 O2 Gas which reforms to pure water.
WARRANTY & CONDITIONS
MECHANICAL WARRANTY: For Descaling Voltrolysis machines ONLY
Secure Supplies private Limited (Secure) warranty that; ‘Secure Supplies Non Electrolytic De-scaler.’ system supplied is brand new, manufactured with first class workmanship and good manufacturing techniques. Mechanical warranty of Secure Supplies lasting 12 months from the date of first start up or 18 months from the FOB (Secure Supplies Factory) delivery date whichever period ends earlier. During the period of mechanical warranty, the customer shall have to notify (with complete details / description about the problems including the model number, Invoice number, date of shipment and current operating conditions) to Secure Supplies; if any defects or deficiencies arises. Secure Supplies shall provide technical assistance and replace the parts if necessary for the removal of the defects and deficiencies. If need be, Customer has to dispatch the defective parts like electrodes / Voltrolysis machines / anodes / cathodes to Secure Supplies site by customer’s responsibility for necessary repairs and rectification. The customer shall bear the transport cost.
LIMITED WARRANTY: For Descaling Voltrolysis machines ONLY
Warranty for electrodes / Voltrolysis machines / anodes / cathodes shall have 60 months on Pro-rata basis from the date of its commissioning. I.e., if any failure in the coating or failure of electrodes / Voltrolysis machines / anodes during the first eighteen months from the date of its commissioning (subject to the condition under mechanical warranty), Secure Supplies shall arrange to repair or replace the electrodes / Voltrolysis machines / anodes if deem required. Thereafter, it will be strictly governed under pro-rata warranty for the remaining period within eighteen months. The interpretation of pro-rata warranty will be governed under International standards and norms.
EXCLUSION: For Descaling Voltrolysis machines ONLY
Our warranty does not cover any damages or injuries resulting from misuse, negligence, and normal expected wear and tear, corrosion due to undue reactions, improper installations, and irregularities in cleaning, operation not in conformity with factory recommendations / user Manual. The warranty won’t cover the electrodes / Voltrolysis machines / anodes / Cathodes that has been modified, tampered with or altered without authorization. No other extended liabilities stated or implied and in no circumstances covers incidental or any consequential damages / injuries / cost resulting from defective products.
POST – WARRANTY: For Descaling Voltrolysis machines ONLY
Once the warranty period is over, the customer / owner is expected to maintain the electrodes / Voltrolysis machines / anodes / Cathodes continuously to enhance maximum life and quality.
The reconditioning or refurbishment of the Unit, if required, shall be the responsibility of the owner and Secure Supplies may be approached for necessary guidance and advice.